Maytag MED6230HW electric dryer

Category
Dryers
Model number
MED6230HW
Region
United States and Canada
Manual
W11555818 revision Rev A
Verified

Error codes

CodeMeaningChecks
L2The dryer ran its installation diagnostic routine at the start of its first cycle and the dryer heater is not turning on. The manual says there might be a power supply problem in the house.Checks
Check VentThe dryer vent may be crushed or blocked.2 causes

L2

An L2 code shows on the first cycle. The dryer ran its installation diagnostic routine at the start of its first cycle and the dryer heater is not turning on. The manual says there might be a power supply problem in the house.

Problems

Odor when the dryer is first heated

The odor is common when the heating element is first used and goes away. Source: Complete Installation Checklist, p. 22

Discoloration at the rear of the drum

Garments with unstable dyes, such as denim blue jeans or brightly colored cotton, may discolor the rear of the drum. These stains are not harmful and will not stain future loads. Source: Dryer Care: Cleaning the dryer interior, p. 27

How-to

Maintenance

TaskWhenSource
Clean the lint screenBefore or after each load Source: Important Safety Instructions; Dryer Care, pp. 4, 27
Wash the lint screen with a nylon brushEvery 6 months, or more often if it clogs from residue Source: Dryer Care: Cleaning the lint screen, p. 27
Clean the dryer drum with mild dish detergent and very warm water Source: Dryer Care: Cleaning the dryer interior, p. 27
Remove lint from inside the dryer cabinet; this should be done by a qualified appliance servicer or ventilation system cleaner (professional service)Every 2 years, or more often depending on dryer usage Source: Dryer Care: Removing accumulated lint, p. 27
Remove lint from the entire length of the exhaust vent system (professional service)At least every 2 years, or more often depending on dryer usage Source: Dryer Care: Removing accumulated lint; Check your vent system for good air flow, pp. 27-28
Remove lint and debris from the exhaust hood Source: Dryer Care: Maintain good air flow, p. 28
Keep the area around the dryer clear of items that block airflow, including piles of laundry in front of it Source: Dryer Care: Cleaning the dryer location, p. 27
Connect or disconnect the dryer's electrical supply (power supply cord or direct wire) (professional service) Source: Electrical Requirements - U.S.A. Only, p. 7
Disconnect the wiring from a direct-wired dryer before moving it (professional service) Source: Non-Use, Storage, and Moving Care, p. 29
Convert the dryer to exhaust through the bottom or sides (professional service) Source: Venting: Plan Vent System, p. 18

Parts and consumables

ItemReplace or refillSpecificationSource
Drum light bulb–10 W appliance bulb (models with a drum light). Source: Dryer Care: Changing the drum light, p. 28

Specifications

Electric dryers need a separate 30 A circuit. Clean the lint screen before or after each load, and do not run the dryer with the lint screen loose, damaged, blocked or missing. Source: Location Requirements; Important Safety Instructions; Dryer Care, pp. 4, 6, 27

At the start of its first cycle the dryer runs an installation diagnostic routine. If the heater is not turning on, it shows an L2 code. If the Airflow screen reads Check Vent, the vent may be crushed or blocked. Source: Complete Installation Checklist, p. 22

The last part of a tumble dryer cycle runs without heat (cool down period). Avoid stopping a cycle before the end unless all items are removed quickly and spread out so the heat dissipates. Source: Important Safety Instructions, p. 4

Electrical supply (U.S.)3- or 4-wire, single-phase 120/240 V, 60 Hz AC (or 120/208 V if specified on the serial/rating plate) on a separate 30 A circuit fused on both sides of the line; no extension cord. A 4-wire connection is required for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile homes Source: Electrical Requirements - U.S.A. Only, p. 7
Electrical supply (Canada)4-wire, single-phase 120/240 V, 60 Hz AC on a separate 30 A circuit; the 5 ft (1.52 m) power cord plugs into a standard 14-30R receptacle Source: Electric Dryer Power Hookup - Canada Only, p. 8
FloorMust support a dryer weight of 200 lb (90.7 kg); level with a maximum slope of 1 in (25 mm) under the entire dryer Source: Location Requirements, p. 6
Installation temperatureDo not operate, install or store where it is exposed to water or weather, or at temperatures below 45 °F (7 °C); lower temperatures may keep the dryer from shutting off at the end of automatic sensor cycles and lengthen drying times Source: Location Requirements, p. 6
Garage installationPlace the dryer at least 18 in (460 mm) above the floor Source: Location Requirements, p. 6
Exhaust vent4 in (102 mm) heavy metal exhaust vent and clamps only; no plastic or metal foil vent; exhaust outdoors, not into a gas vent, chimney, wall, ceiling, attic, crawl space or concealed space; seal joints with clamps, not screws or duct tape; no booster fan in the exhaust duct Source: Venting: Venting Requirements, pp. 4, 17
Exhaust hoodAt least 12 in (305 mm) from the ground or any object that may obstruct the exhaust, such as flowers, rocks, bushes or snow Source: Venting: Venting Requirements, p. 17
Flexible metal ventAcceptable only if accessible to clean; fully extended and supported; total length not more than 7 3/4 ft (2.4 m); not in enclosed walls, ceilings or floors Source: Venting: Venting Requirements, p. 17
Maximum vent length, rigid metal with angled hood0 turns 64 ft (20 m); 1 turn 54 ft (16.5 m); 2 turns 44 ft (13.4 m); 3 turns 35 ft (10.7 m); 4 turns 27 ft (8.2 m). Bottom exhaust installations have a 90° turn inside the dryer, so add one turn when reading the chart Source: Venting: Plan Vent System, p. 18
ElbowsNo more than four 90° elbows in a vent system; 45° elbows give better airflow than 90° elbows Source: Venting; Dryer Care: Maintain good air flow, pp. 17, 28
Closet installationA closet door needs ventilation openings in the top and bottom of the door; louvered doors with equivalent openings are acceptable; 1 in (25 mm) extra space on all sides is recommended to reduce noise transfer; no other fuel-burning appliance in the same closet Source: Location Requirements, p. 6
Drum light bulb (some models)10 W appliance bulb only Source: Dryer Care: Changing the drum light, p. 28

Recalls

No exact-model match for MED6230HW in the U.S. Consumer Product Safety Commission recall database, checked . Recalls can name model families, so also check current recalls for Maytag.

Sources

  1. Dryer Installation and Care Instructions Manual. Whirlpool Corporation (Maytag). Document W11555818, revision Rev A, 88 pages, en-US. maytag.com (PDF). Listed on the manufacturer's support page. Retrieved 13 November 2026.

Page numbers are the numbers printed in the manual. Where this page and the manual differ, follow the manual.

Applies to
MED6230HW. United States and Canada.
Source
Dryer Installation and Care Instructions Manual, W11555818 revision Rev A
Last verified

All Maytag handbooks. Report an error to hello@modelhandbook.com.