Brother HL-L2460DW error Drum !

The corona wire on the drum unit needs cleaning, or the drum unit is not seated.

Cause 1 of 2The corona wire on the drum unit must be cleaned. Source: Troubleshooting: Error and Maintenance Messages, p. 153

First checkClean the corona wire on the drum unit.

Causes and checks

  1. The corona wire on the drum unit must be cleaned. Source: Troubleshooting: Error and Maintenance Messages, p. 153

    1. Clean the corona wire on the drum unit. See Clean the corona wire.
    2. If the message remains, replace the drum unit with a new one.
  2. The drum unit, or the toner cartridge and drum unit assembly, is not installed correctly. Source: Troubleshooting: Error and Maintenance Messages, p. 153

    1. Remove the drum unit from the machine.
    2. Take the toner cartridge out of the drum unit and put it back in.
    3. Install the drum unit in the machine.

Service

If the checks above do not clear it, contact Brother Customer Service: 1-877-BROTHER (1-877-276-8437), brother-usa.com/support. USA (phone and www.brother-usa.com/support); Canada (www.brother.ca/support). Source: Appendix: Brother Help and Customer Support, p. 249

Other HL-L2460DW codes

Sources

  1. Online User's Guide, HL-L2400D / HL-L2405W / HL-L2420DW / HL-L2460DW / HL-L2460DWXL / HL-L2865DW. Brother Industries, Ltd. Document cv_hll2460dw_use, revision PDF created 2023-11-28, 256 pages, en-US. support.brother.com (PDF). Listed on the manufacturer's support page. Retrieved 13 November 2026.

Page numbers are the numbers printed in the manual. Where this page and the manual differ, follow the manual.

Applies to
HL-L2460DW (variant HL-L2460DWXL). United States and Canada.
Source
Online User's Guide, HL-L2400D / HL-L2405W / HL-L2420DW / HL-L2460DW / HL-L2460DWXL / HL-L2865DW, cv_hll2460dw_use revision PDF created 2023-11-28
Last verified
Handbook
Brother HL-L2460DW laser printer in Printers; all Brother handbooks