Epson ET-4850 “E-10 (network report)”

The IP address, subnet mask and default gateway setup needs confirming.

CauseThe manual TCP/IP values are wrong, or DHCP and the Manual setting conflict. Source: Network Connection Report Codes and Messages, p. 51

First checkTurn on the other devices on the network.

Causes and checks

  1. The manual TCP/IP values are wrong, or DHCP and the Manual setting conflict. Source: Network Connection Report Codes and Messages, p. 51

    1. Turn on the other devices on the network.
    2. With Obtain IP Address set to Manual, compare the IP address, subnet mask and default gateway on the report with your network and fix any that are wrong.
    3. With DHCP enabled, set Obtain IP Address to Auto. To use the DHCP address as a static one, set Manual, enter the IP address from the report and use the subnet mask 255.255.255.0.
    4. If it still does not connect, switch the router or access point off, wait about 10 seconds and on again.

Service

If the checks above do not clear it, contact Epson America technical support: (562) 276-4382, epson.com/support. United States, 6 AM to 8 PM Pacific Time, Monday through Friday, and 7 AM to 4 PM Pacific Time, Saturday. Canada: (905) 709-3839, same hours (epson.ca/support). Source: Where to Get Help, p. 310

Other ET-4850 codes

Sources

  1. User's Guide, ET-4850. Epson America, Inc. Document CPD-60205, revision CPD-60205R1, 333 pages, en-US. files.support.epson.com (PDF). Listed on the manufacturer's support page. Retrieved 13 November 2026.

Page numbers are the numbers printed in the manual. Where this page and the manual differ, follow the manual.

Applies to
ET-4850. United States and Canada.
Source
User's Guide, ET-4850, CPD-60205 revision CPD-60205R1
Last verified
Handbook
Epson EcoTank ET-4850 printer in Printers; all Epson handbooks