Samsung DVE50R5400W how to run the vent blockage test

After installing the dryer, to check that the duct system is installed properly. The test must run when the dryer is cool.

Steps

  1. Make sure the drum is empty, and then close the door.
  2. Press the Power button to turn the dryer on, then press and hold the Adjust Time and Dryness buttons together for 3 seconds. InS or In appears in the display.
  3. Press the Start/Pause (Hold to Start) button. The test starts immediately and takes about 2 minutes. Do not open the door during the test.
  4. Read the result. If the duct system is normal, 0 appears and the dryer sounds a completion tone. Otherwise a check code appears and the dryer sounds an alarm tone.

If the dryer warms up after the installation check, run the AIR FLUFF cycle for several minutes to reduce its internal temperature. The drum is hot during and after the test. To cancel the test, press Power. The result stays on the display for about 5 minutes. A normal result does not rule out a slightly blocked duct system.

Source: Installation: Vent blockage test Source: Installation: Vent blockage test, p. 28

Other DVE50R5400W procedures

Sources

  1. User manual, Dryer DVE(G)50R5400* / DVE(G)50T5300* / DVE(G)50R5200*. Samsung Electronics America, Inc. Document DC68-03784D-14, revision 14, 56 pages, en. downloadcenter.samsung.com (PDF). Listed on the manufacturer's support page. Retrieved 13 November 2026.

Page numbers are the numbers printed in the manual. Where this page and the manual differ, follow the manual.

Applies to
DVE50R5400W. United States.
Source
User manual, Dryer DVE(G)50R5400* / DVE(G)50T5300* / DVE(G)50R5200*, DC68-03784D-14 revision 14
Last verified
Handbook
Samsung DVE50R5400W electric steam dryer in Dryers; all Samsung handbooks